User`s guide
CARROLL TOUCH Appendix A - Error Messages
Touch System Diagnostics (CTDIAG) User’s Guide A-7
Message: IO address is not on an 8 byte
boundary***
Meaning: The selected RS-232 I/O address is not on an 8-byte
boundary.
Action: Change the I/O address to a correct address on an 8-byte
boundary. The last digit must equal 0 or 8, such as 2F0H
or 2F8H.
Message: IO address is not on an 16 byte
boundary***
Meaning: The selected HBC I/O address is not on a 16 byte
boundary.
Action: Change the I/O address to a correct address on a 16 byte
boundary. The last digit must equal 0, such as 2F0H.
Message: IO address is not within range***
Meaning: The selected I/O address is not within the allowable
address range.
Action: Select an I/O address within the acceptable range of the
controller or comm port.
Message: No CTDIAG.CFG found...
Meaning: CTDIAG attempts to execute autodetection and no
.CFG file can be found.
Action: If no .CFG file is found, CTDIAG uses the
autodetection command line parameters or, if none, the
CTDIAG default parameters. If desired, terminate
CTDIAG, copy a .CFG file into the current directory,
and restart.
Message: No serial ports found
Meaning: CTDIAG found no serial ports installed in the PC when
the Serial (RS-232) option was selected from the Test
Configuration Menu.
Action: You must have a serial port in the PC to use CTDIAG to
test an RS-232 controller or Smart-Frame system.
Table A-1. Error Messages (Continued)