Specifications
AE/LZB 119 1897 R1A SOFTWARE CONFIGURATION
36
6.2.2.3.7 Setup Utilized At Console Start-Up
The number entered in the Startup Setup text box specifies which one of the ten (10) setups the console will operate
with when it is started. These setups correspond to the ten console user profiles established at the CEC/IMC Manager for the
console. Each setup also stores its own standard communication module programming. Upon first running the Configuration
Editor and accessing this dialog box, the displayed setup number always reflects the number of the last setup utilized by the
console application. To start the console with a different setup, enter the respective number (1 — 10) and save the change.
6.2.2.3.8 Call Director Interconnect Hang-Time
The Interconnect Hang Time text box specifies the hang-time (in seconds) utilized during Call Director operations. In
most cases, this setting should remain at 30 seconds, the factory default setting.
6.2.2.3.9 Call Director Patch Volume
Using the CD Patch Volume text box, set the Call Director’s patch volume as required. This is the volume level setting
used between CIM and the Call Director when a CD patch is activated. The valid range is 0 — 10. This setting is always used
for CD patch operations regardless of the patched module’s(s’) previous volume setting(s). When the CD patch terminates,
the module volume setting(s) returns to the previously set value(s).
This value is ignored during normal (local) console-to-CD connections when no radio units are involved. It is also
ignored if the console is not equipped with a Call Director.