Specifications

Command Descriptions 85
ID ('i')
Function: Provides various information about the controller and touchscreen.
The Type byte indicates the touchscreen type selected by the jumpers on the
controller as follows: an ASCII '0' for AccuTouch, '1' for DuraTouch, and '2' for
IntelliTouch.
The IO byte indicates the type of communication interface that is in use by the
controller as follows: an ASCII '0' for serial, '1' for PC-Bus, and '2' for Micro
Channel.
The Features byte indicates installed features of the controller and has the
following bit positions:
Bit Feature
0 Reserved
1 Reserved
2 Reserved
3 Reserved
4 Reserved - External A/D converter
5 Reserved - RAM is 32K bytes
6 Reserved - RAM available
7 Reserved - Z-axis available
The Minor byte reports the minor firmware revision level. The Major byte reports
the major firmware revision level. These bytes may be treated as an integer.
The P byte reports the number of packets to expect when querying the
configuration with the 'g' command, not including the Acknowledge packet that
follows. P may change with future firmware revisions.
The IFlag byte indicates the model of serial controller. Bit 0 is set if the controller
is an E271-2210, or clear if it is an E271-2200. The E271-2210 controller is
software compatible with the E271-2200 with the following exceptions:
Low Power Mode is not supported. See Low Power command, page 89.
38,400 Baud is not supported. See Parameter command, page 95.
Filtering parameters are slightly different. See Filter command, page 82.