92 Chapter 6 - Command Reference
is set below the natural variation of
coordinates for a constant touch. Tracking
Mode requires Stream Mode (bit 1 of Mode1
above).
7 Reserved
The controller modes may also be configured with an ASCII packet. XXXXXX
represents any of the following values in string form.
'I' Report Initial Touches
'S' Report Stream Touches
'U' Report Untouches
'T' Enable Tracking Mode
'P' Enable Trim Mode
'C' Enable Calibration (automatic if 'P' selected)
'M' Enable Scaling
'B' Enable Range Checking (automatic if 'P' selected)
If an invalid character is present in the string, the remainder of the string is
ignored.
When the ASCII version of the Mode command is received, it starts by disabling
all modes and reporting options. The ASCII codes that follow then enable the
specified modes and reporting options. Because the XXXXXXX string may be a
maximum of 7 characters, and more than 7 modes are available, the 'P' character
also enables the Calibration and Range Checking Modes.
If the Initial Touch, Stream, and Untouch Modes are disabled, no Touch packets
will be transmitted unless a Touch query is issued. See Touch command, page 102.
The factory default mode has Initial Touches, Stream Touches, and Untouches
enabled. The Single-Point Mode jumper (J4) disables Stream Touches and