USER MANUAL Elo Touch Solutions 1929LM Touchmonitor SW200158 Rev A
Copyright © 2014 Elo Touch Solutions, Inc. All Rights Reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, including, but not limited to, electronic, magnetic, optical, chemical, manual, or otherwise without prior written permission of Elo Touch Solutions, Inc. Disclaimer The information in this document is subject to change without notice. Elo Touch Solutions, Inc.
Warnings and Cautions Warning • Danger - Explosion hazard. Do not use in the presence of flammable anesthetics, and other flammable materials. • To prevent fire or shock hazards, do not immerse the unit in water or expose it to rain or moisture. • Do not use the unit with an extension cord receptacle or other outlets unless the prongs of the power cord can be fully inserted. • RISK OF ELECTRICAL SHOCK - DO NOT OPEN.
Caution Power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord. This unit must follow the national requirement and local state laws to dispose unit. Before connecting the cables to your Elo Touchmonitor, make sure all components are powered OFF. Only approved components complying with IEC60601-1 series can be connected to 1929LM touch monitor for Healthcare Applications in Patient Environment.
Classification With respect to electrical shock, fire in accordance with ANSI/AAMI ES60601-1:2005 and CAN/CSA C22.2 No. 60601-1-08 This Touchmonitor is a Class I (GROUNDED) DEVICE. These Touchmonitors are classified NO APPLIED PARTS EQUIPMENT. Protection against harmful ingress of water: INGRESS PROTECTION (IPX1) This Touchmonitor shall be classified as ORDINARY EQUIPMENT, not intended or evaluated for use in the presence of flammable anesthetic mixture with air, oxygen, or nitrous oxide.
European Standards and Classifications Standards: EN 60601-1-2: 2007 The EMC limits and test methods are referred to the following standards: Emission: Immunity CISPR11:2009+A1:2010 ED. 5.1(Grp I, Class B) AS/NZS CISPR 11: 2011, Grp. 1, Class B IEC61000-4-2:2008 ED.2.0 IEC61000-4-3:2006+A1:2007 +A2:2010ED.3.2 IEC 61000-4-4: 2012 ED.3.0 EN 61000-3-2: 2006 +A1: 2008+A2: 2009, Class D IEC 61000-4-5: 2005 ED.2.0 IEC 61000-3-3: 2008 IEC 610004-6: 2008 ED.3.0 IEC 61000-4-8: 2009 ED.2.
Guidance and manufacturer’s declaration-electromagnetic immunity for all EQUIPMENT AND SYSTEMS Guidance and manufacturer’s declaration-electromagnetic emissions The 1929LM Touchmonitor for Healthcare Applications is intended for use in the electromagnetic environment specified below. The customer or the user of the 1929LM Touchmonitor for Healthcare Applications should assure that it is used in such an environment.
Guidance and manufacturer’s declaration-electromagnetic immunity – for all ME EQUIPMENT AND ME SYSTEMS Guidance and manufacturer’s declaration-electromagnetic immunityError! Bookmark not defined. The 1929LM Touchmonitor for Healthcare Applications is intended for use in the electromagnetic environment specified below. The customer, or the user of the 1929LM Touchmonitor for Healthcare Applications, should assure that it is used in such an environment.
Guidance and manufacturer’s declaration-electromagnetic immunity for all EQUIPMENT AND SYSTEMS that are not LIFE-SUPPORTING Guidance and manufacturer’s declaration-electromagnetic immunity The 1929LM Touchmonitor for Healthcare Applications is intended for use in the electromagnetic environment specified below. The user of the 1929LM Touchmonitor for Healthcare Applications should assure that it is used in such an environment.
Recommended separation distances between portable and mobile RF communications equipment and the 1929LM Touchmonitor for Healthcare The 1929LM Touchmonitor for Healthcare Applications is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
Table of Contents Chapter 1: Introduction .............................................................................. 12 Chapter 2: Installation ................................................................................ 13 Chapter 3: Mounting ................................................................................... 17 Chapter 4: Operation .................................................................................. 19 Chapter 5: Technical Support ....................................
Chapter 1: Introduction Product Description Your new touchmonitor combines Elo Touch Solutions’ reliable performance with the latest developments in touch technology and display design. This combination of features creates a natural flow of information between a user and the touchmonitor. This touchmonitor incorporates an 8-bit color, active matrix thin-film-transistor LCD panel to provide high quality display performance. Its resolution of 1280x1024 is suitable for displaying graphics and images.
Chapter 2: Installation Unpacking the Touch monitor Open the carton and verify the following items are present: Touchmonitor with protective sheet for its face US Medical Power Cable – 1.8M EU Power Cable – 1.8M VGA Cable – 1.8M DVI to HDMI Cable – 1.8M USB Cable – 1.8M Serial Cable – 1.8M Audio Cable – 1.8M Elo Driver CD Quick Install Guide User Guide CD Connector Panel & Interfaces Remove the cable cover on the back of the unit to access the Touchmonitor’s connector panel.
Touchmonitor Connections 1. Connect the DVI to HDMI or VGA video cables between the monitor’s HDMI/VGA input connectors and your DVI/VGA video source, respectively. Tighten the video cable’s screws for best performance. 2. Connect the USB touch cable between the monitor’s USB connector and your PC’s USB port. 3. Connect the audio cable between the monitor’s Audio In jack and your audio source. 4. Select the correct power cable for your region.
Installing the Touch Technology Software Drivers Some software installation is required for your Touchmonitor to work with your computer. The drivers for the Windows 7, XP, Vista, WePOS, and 32-bit Server 2003 operating systems are provided with your Touchmonitor on a CD. Visit the Elo Touch Solutions website www.elotouch.
For Windows 7 installations, check the “Install driver” box under “Elo USB Interfaces – Other Touchscreens” After accepting the end-user license agreement, the drivers will finish installing. Reboot your computer after the install is complete. © 2014 Elo Touch Solutions, Inc. All rights reserved.
Chapter 3: Mounting Rear VESA Mount A four-hole 100x100mm mounting pattern for M4 screws is provided on the rear of the monitor. Remove the stand using a Phillips screwdriver to access this mounting interface. The VESA FDMI-compliant mounting is coded: VESA MIS-D, 100, C © 2014 Elo Touch Solutions, Inc. All rights reserved.
Stand Mounting Threaded through-holes are provided on the bottom of the stand base for mounting or securing. VESA Mounting OptionsError! Bookmark not defined. The following companies provide VESA mounting devices compatible with your touch monitor : GCX 800-228-2555 707-773-1100 www.gcx.com Ergotron 800-888-8458 651-681-7600 www.ergotron.com Innovative Office Products 800-524-2744 610-253-9554 www.innov-office-prod.com MRI 800-688-2414 www.mediarecovery.com © 2014 Elo Touch Solutions, Inc.
Chapter 4: Operation Power To turn the Touchmonitor on or off, press the Touchmonitor power button once. The Power Status LED on the bottom of the Touchmonitor functions according to the following table: Touchmonitor/Computer Module status OFF SLEEP ON LED statusError! Bookmark not defined. OFF ORANGE GREEN The system consumes low power when in SLEEP and OFF modes. For detailed power consumption specifications, refer to technical specifications on the Elo website http://www.elotouch.
Your Touchmonitor will likely not require video adjustments. However, for analog VGA video, variations in video graphic card outputs may require user adjustments through the OSD to optimize the quality of the Touchmonitor’s displayed image. These adjustments are “remembered” by the Touchmonitor. Also, to reduce the need for adjustments for different video mode timings, the monitor correctly scales and displays some of the video industry’s most common video timing modes.
Auto Adjust H-position V-position Aspect Ratio Sharpness Color TemperatureError! Bookmark not defined.Error! Bookmark not defined. OSD Timeout OSD LanguageError! Bookmark not defined. Information Power Off 5s Timer Audio source Volume MuteError! Bookmark not defined. Automatically adjusts the system clock to the input analog VGA video signal, affecting the H-position, V-position, Clock, and Phase menu items.
Recall Defaults Input Select Selecting “Recall Defaults” restores all factory default settings for OSD-adjustable parameters (except OSD Language) and for Preset Video Mode timings. The monitor continually scans for active video on the VGA ,HDMI and DisplayPort connectors. This adjustment selects which of those input ports should be given priority to be displayed.
Chapter 5: Technical Support If you are experiencing trouble with your Touchmonitor, refer to the following suggestions. If the problem persists, please contact your local dealer or contact Elo Touch Solutions Customer Service. Solutions to Common Problems Problem Suggested Troubleshooting Check that the AC power cable is properly The Touchmonitor does not respond when connected. turning on the system. Verify the AC power source is functioning. Use the OSD to increase the brightness.
Chapter 6: Safety & Maintenance Safety To avoid risk of electric shock, follow all safety notices and do not disassemble the Touchmonitor. They are not user-serviceable. The slots located on the sides and top of the Touchmonitor case are for ventilation. Do not block or insert anything inside the ventilation slots. The touch monitor ships with a 3-wire, grounding power cord. The power cord plug only fits into a grounded outlet.
Chapter 7: Regulatory InformationError! Bookmark not defined. I. Electrical Safety Information: Compliance is required with respect to the voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified herein will likely result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed. There are no operator serviceable parts inside this equipment.
iv) Plug the digital device into a different AC outlet so the digital device and the receiver are on different branch circuits. v) Disconnect and remove any I/O cables that the digital device does not use.(Un-terminated I/O cables are a potential source of high RF emission levels.) vi) Plug the digital device into only a grounded outlet receptacle. Do not use AC adapter plugs. (Removing or cutting the line cord ground may increase RF emission levels and may also present a lethal shock hazard to the user.
IV. China RoHS In accordance to Chinese law (Administration on the Control of Pollution Caused by Electronic Information Products), the section below lists out the name and amount of the toxic and/or hazardous materials that this product may contain.
V. Power Adapter Specifications Electrical Ratings: Input: 100-240VAC, 60/50Hz Output: 12VDC, minimum 3A, LPS VI. Monitor Specifications Electrical Ratings: Input: 12VDC, 3A Operating Conditions: Temperature: 0°C – 40°C Humidity: 20% to 80% (non-condensing) Altitude: 0 to 3,048m Storage Conditions: Temperature: -20°C – 60°C Humidity: 10% to 90% (non-condensing) Altitude: 0 to 12,192m VII. End of Life DisposalError! Bookmark not defined.
Chapter 8: Warranty Information Except as otherwise stated herein, or in an order acknowledgment delivered to Buyer, Seller warrants to Buyer that the Product shall be free of defects in materials and workmanship. The warranty for the Touchmonitors and their components is three years. Seller makes no warranty regarding the model life of components. Seller’s suppliers may at any time and from time to time make changes in the components delivered as Products or components.
Index Agency Certifications, 26 Mute, 21 Altitude, 5 native resolution, 19 Audio, 22 online self-help, 23 brightness, 20 On-Screen Display, 20 calibration, 19 Operating, 5 Care and Handling, 24 OSD, 20 China RoHS, 27 OSD buttons, 20 Classification, 5 OSD Language, 21 cleaning, 24 Out Of Range, 23 Color Temperature, 21 Power Adapter Specifications, 28 Connections, 14 Power Status LED, 19 Connector Panel & Interfaces, 13 Precautions, 12 contrast, 20 Disclaimer, 2 Problems, 23 Out of R
Check out our website www.elotouch.com Get the latest... Product Information Specifications Upcoming events Press releases Software drivers Getting in Touch with Us To find out more about the extensive range of Elo touch solutions, visit our website at www.elotouch.com, or simply call the office nearest you: North America Elo Touch Solutions 1033 McCarthy Blvd Milpitas, CA 95035 Tel 800-ELO-TOUCH Tel + 1 408 597 8000 Fax +1 408 597 8050 customerservice@elotouch.