4.1.7. Built-In Protection
• Software error handling
• Abort (hard stops and soft stops)
• Status reporting
• Protection against:
Shorts between motor power outputs
Shorts between motor power output and power input/return
Failure of internal power supplies
Over temperature
• Cont. temperature measurement. Temp can be read on the fly, Warning can be
initiated X degrees before temp disable is activated.
Over/Under voltage
Loss of feedback
Following error
Current limits
4.1.8. Accessories
• External heatsink (Whistle). See Section 3.4.1 for more details. Catalog number:
WHI-HEATSINK-2.
• Evaluation Board. See Section 3.16 for a picture and more details. Catalog number:
EVA-WHI/GUI/BEL.
• Cable Kit. See Section 3.16 for more details. Catalog number: CBL-EVAUNIKIT01.
4.1.9. Status Indication
• Output for a bi-color LED
4.1.10. Automatic Procedures
• Commutation alignment
• Phase sequencing
• Current loop offset adjustment
• Current loop gain tuning
• Current gain scheduling
• Velocity loop offset adjustment
• Velocity gain tuning
• Velocity gain scheduling
• Position gain tuning