User Manual

Solo Whistle Installation Guide Technical Specifications
MAN-SOLWHIIG (Ver. 1.503)
www.elmomc.com
63
4.7.2.6. Potentiometer
Feature Details
Potentiometer Format Single-ended
Operating Voltage Range 0 to 5 V supplied by the Solo Whistle
Potentiometer Resistance 100 Ω to 1 kΩ … above this range, linearity is
affected detrimentally
Input Resistance 100 kΩ
Resolution 14 bit
4.7.3. Auxiliary Feedback Port (output mode YA[4]= 4)
Feature Details
Encoder output and main buffered
output
A, B, Index
Differential outputs
Quadrature
Interface RS-422
Output current capability
Driving differential loads of 200 on
INDEX/INDEX-, CHB/CHB- and CHA/CHA- pairs
Available as options
Simultaneous buffered outputs of main-
incremental encoder input
Simultaneous emulated encoder outputs of
analog encoder input
Simultaneous emulated encoder outputs of
resolver input
Maximum frequency f
MAX
: 5 MHz pulses/output
Index (marker) Length of pulse is one quadrature (one quarter of
an encoder cycle) and synchronized to A&B