4.8. Communications
Specification Details
RS-232
Signals:
RxD, TxD, Gnd
Full duplex, serial communication for setup and control
Baud Rate of 9,600 to 57,600 bit/sec
CAN CAN bus Signals:
CAN_H, CAN_L, CAN_GND
Maximum Baud Rate of 1 Mbit/sec
Version:
DS 301 v4.01
Layer Setting Service and Protocol Support:
DS 305
Device Profile (drive and motion control):
DS 402
4.9. Pulse-Width Modulation (PWM)
Feature Details
PWM resolution 12-bit
PWM switching frequency on the load 2/Ts (factory default 22 kHz on the motor)