Installation Guide Manual
Trombone Installation Guide Technical Specifications
MAN-TROIG (Ver. 1.403)
www.elmomc.com
79
4.6.4. Auxiliary Feedback Port (input mode YA[4]= 2, 0)
Feature Details
Encoder input,
pulse and direction input
• A, B, Index
• Single ended
Input voltage V
In
Low: 0 V < V
IL
< 0.8 V
V
In
High: 2 V < V
IH
< 5 V
Maximum absolute voltage: 0 < V
In
< 5.5 V
Input current: ±1 µA
Available as options
• Single-ended Encoder inputs
• Pulse and Direction inputs
Edge separation between A & B Programmable number of clocks to allow adequate
noise filtering at remote receiver of emulated
encoder signals
Index (marker): Length of pulse is one quadrature (one quarter of
an encoder cycle) and synchronized to A&B
Figure 40: Auxiliary Feedback - Encoder Phase Diagram