4.3. Power Ratings
Feature Units 12/400 16/400 R17/400 R22/400 8/800 12/800 R11/800 R16/800
Minimum supply
voltage
VDC S suffix in P/N*: 50
No S suffix in P/N: 100
S suffix in P/N*: 95+
Nominal supply
voltage
VDC 325 560 for 400 VAC
680 for 480 VAC
Maximum supply
voltage
VDC 400 780
Maximum continuous
power output
W Up to 10 kW of continuous qualitative power
Efficiency at rated
power (at nominal
conditions)
% > 98
Auxiliary supply
voltage option
VDC 18 V to 30 V
Only for Control Supply S suffix Model
Auxiliary power
supply
VA ≤5 VA without external loading
≤8 VA with full external loading
Continuous current
limit (Ic) Amplitude
sinusoidal/DC
trapezoidal
commutation
A 12 16 17 22 8 12 11 16
Sinusoidal continuous
RMS current limit (Ic)
A 8.5 11.3 12 15.5 5.7 8.5 7.8 11.3
Peak current limit A 2 x Ic No peak 2 x Ic No peak
Weight g (oz) 250 g (8.8 oz)
Dimensions mm
(in)
111 x 76 x 30 (4.33" x 2.95" x 1.18")
Digital in/Digital out/
Analog in
6/4/1
Mounting method PCB Mounted
*See page 17 for details on the part number. The S suffix appears in models where there is a
24 V control supply. If there is no S suffix, the control power supply operates from the main
power.
Note on current ratings: The current ratings of the Trombone are given in units of DC
amperes (ratings that are used for trapezoidal commutation or DC motors). The RMS