4.7.4. Auxiliary Feedback Port (output mode YA[4]= 4)
Feature Details
Emulated output
• A, B, Index
• Differential outputs
Output current capability Maximum output current: I
OH
(max) = 2 mA
High level output voltage: V
OH
> 3.0 V
Minimum output current: I
OL
= 2 mA
Low level output voltage: V
OL
< 0.4 V
Available as options
• Emulated encoder outputs of analog encoder
• Emulated encoder outputs of the resolver
• Emulated encoder outputs of the tachometer
• Emulated encoder outputs of the
potentiometer
Maximum frequency f
MAX
: 5 MHz pulses/output
Edge separation between A & B
Programmable number of clocks to allow adequate
noise filtering at remote receiver of emulated
encoder signals
Index (marker): Length of pulse is one quadrature (one quarter of
an encoder cycle) and synchronized to A&B
Figure 33: Auxiliary Feedback - Encoder Phase Diagram