4.3. Power Ratings for the 400 V Type
Feature Units 6/400 12/400 16/400 R17/400 R22/400
Minimum supply voltage VDC S option in P/N: 50
No S option in P/N: 100
Nominal supply voltage VDC 325
Maximum supply voltage VDC 400
Maximum continuous
power output
kW 2 4 5 5.5 7
Efficiency at rated power
(at nominal conditions)
% > 98
Auxiliary supply voltage
option
VDC 18 V to 30 V
Only for Control Supply S option Model
Auxiliary power supply VA ≤5 VA without external loading
7 VA with full external loading
Continuous current limit
(Ic) Amplitude
sinusoidal/DC trapezoidal
commutation
A 6 12 16 17 22
Sinusoidal continuous RMS
current limit (Ic)
A 4.2 8.5 11.3 12 15.5
Peak current limit A 2 x Ic No peak
Weight g (oz)
650 g (22.9 oz) for standard L shape
1100 g (38.8 oz) for L shape fins and fan
Dimensions mm
(in)
140 x 105 x 43 (5.51" x 4.13" x 1.7")
for standard L shape
Digital in/Digital out/ Analog in 6/4/1
Mounting method Panel / Wall Mounted