.22 Feedbacks
.22.1 Feedback Supply Voltage
Feature
Details
Main encoder supply voltage
5 V +5% @ 200 mA maximum
Auxiliary encoder supply voltage
5 V +5% @ 200 mA maximum
.23 I/Os
The Evaluation Board has: 6 Digital Inputs; 1 Analog Input and 2 Digital Outputs (Whistle
and Bell) or 4 Digital Outputs (Guitar).
.23.1 Digital Input Interfaces
Feature
Details
Type of input
Optically isolated
Single ended
PLC level
Input current
mA
K
VVin
Iin
2.
1
43
.3
5.1
max
=
@Vin= 5V
mA
K
VVin
Iin 7.6
43.
3
1
max
=
@Vin= 30V
High-level input voltage
5 V < Vin < 30 V, 5 V typical
Low-level input voltage
0 V < Vin < 1 V
Minimum pulse width
> 4 x TS, where TS is sampling time
Execution time
(all inputs):
the time from application of
voltage on input u
ntil
execution is complete
If input is set to one of the built
-in functions Home,
Inhibit, Hard Stop, Soft Stop, Hard and Soft Stop,
Forward Limit, Reverse Limit or Begin
execution is
immediate upon detection:
0 < T < 4 x TS
If input is set to General
Input, execution depends on the
program. Typical execution time:
0.5 msec.
J2: General