Owner's manual
Table Of Contents
- Notice
- Catalog Number
- Revision History
- Elmo Worldwide
- Table of Contents
- Chapter 1: Safety Information
- Chapter 2: Introduction
- Chapter 3: Installation
- Chapter 4: Servo Control Operation
- Chapter 5: Technical Specifications

Cymbal Installation Guide Servo Control Operation
MAN-CYMIG (Ver. 1.3)
35
4.4. Status Indications
ThefollowingtableliststheCymbalamplifierstatusindications.
Function
Latch
Option
AOK
SO1
SO2
SO3
1 AmplifierOK(AOK) N/A Low Opencollector Opencollector Opencollector
2 Externaldisable No Low Low Opencollector Low
3 Currentlimit No Low Opencollector Opencollector Low
4 Short Yes Open
collector
Low Opencollector Low
5 Overtemperature Yes Open
collector
Opencollector Low Low
6 Internalsupplies
protection
No Open
collector
Low Low Opencollector
7 Undervoltage No Open
collector
Low Opencollector Opencollector
8 Overvoltage No Open
collector
Opencollector Low Opencollector
9 Shunt* No Low Opencollector Low Opencollector
10 Powerupreset No Open
collector
Opencollector Opencollector Opencollector
11 Commutationfailure Yes Open
collector
Low Low Low
*Thisindicationcanbeusedasadigitalinputforactivatinganexternalshuntregulator.
Table10:CymbalStatusIndications
Notes:
• Withoutlatchmode:
Thestatusindicationsareresetwhenthefaultdisappears.
• Withlatchmode:
TheShort,OverTemperatureandCommutationFailurestatusindicationsareresetwhen
theenablesignalistemporarilyremovedfromtheenableinput.
• Multiplefaults:
Onlythereadingofthefirstfaultisreliable.Additionalfaultsaddontothestatusoutputs
andtheindicationisthereforemeaningless.