Owner's manual
Table Of Contents
- Notice
- Catalog Number
- Revision History
- Elmo Worldwide
- Table of Contents
- Chapter 1: Safety Information
- Chapter 2: Introduction
- Chapter 3: Installation
- Chapter 4: Servo Control Operation
- Chapter 5: Technical Specifications

Cymbal Installation Guide Installation
MAN-CYMIG (Ver. 1.3)
23
Pin Signal Function PinPosition
J1‐9 Backup+Supply +VDCbackupsupply
J1‐8 Backup‐Supply Return(common)ofthebackup
supply
Table6:BackupCablePlug
Figure9:BackupSupplyConnectionDiagram
Note: ThereturnofthebackupsupplymustnotbeconnectedtoPE,assuchaconnectioncan
damagethedrive.
“Smart”Control
SupplyOptions
InternalDC‐to‐DCconverterthatallowsoperationfromDCpower(no
needforauxiliaryexternalsupplyfornormaloperation).
12to195VDCsupplyforbackingupthecontrolparametersifDCpower
isshutoff.
J1
Male
www.elmomc.com