3.5.1.1. ConnectingtheMotorCable
ConnectthemotorpowercabletotheM1,M2,and M3terminalsofthemainpowerconnector
andthefourthwiretothePE(ProtectiveEarth)ontheheatsink(seediagramabove).
Notesforconnectingthemotorcables:
Forbestimmunity,itishighlyrecommendedtouseashielded(nottwisted)cableforthe
motorconnection.A4wireshieldedcableshouldbeused.Thegaugeisdeterminedbythe
actualcurrentconsumptionofthemotor.
Connecttheshieldofthecabletotheclosestgroundconnectionatthemotorend.
ConnecttheshieldofthecabletothePEterminalontheheatsink.
Besurethatthemotorchassisisproperlygrounded.
Toclosethemotorcableintothedrive,usethebarrelconnector,M6springwasherand
M6nut(inthedrive).Therequiredtorqueis3to4Nm.
ToclosethePEwireintothedrive,usethebarrelconnector,M5flatwasher,M5spring
washerandM5screwtotheheatsink.Therequiredtorqueis3to4Nm.
Useflexwire6/8/10AWGtobarrelconnector.
Figure4:ACMotorPowerConnectionDiagram
3.5.1.2. ConnectingtheDCPower
ThePowerstageoftheCymbalisfullyisolatedfromothersectionsoftheCymbal,suchasthe
controlstageandtheheatsink.ThiscontributesverysignificantlytothesafetyandtheEMI
immunityoftheCymbal.InadditionitsimplifiestherequirementsoftheDCpowersupplyused
topowertheDCbusoftheCymbalandallowsalsotheoperationwithanonisolatedDCpower
source.
3.5.1.2.a OperationwithanIsolatedDCpowerSupply
ThePE(ProtectiveGroundoftheACnetwork)isconnectedtotheVN‐terminal(theNegative
PowerInputterminal).
www.elmomc.com