Instruction Manual

Maestro Software Manual DS402 Command Reference
MAN-MASSW (Ver. Q)
10-37
ato - status word waiting timeout (for wswd command (or awm property),
default value – 500 milliseconds )
awm - motion completed waiting
amc - motion completed callback control (must be set to 1 for callback
mechanism activation)
Vector properties connected to HM mode (for more information, view the properties
description for axis):
vto - status word waiting timeout
vwm - motion completed waiting
vmc - motion completed callback control
Group properties connected to HM mode (for more information, view the properties
description for axis):
gto - status word waiting timeout
gwm - motion completed waiting
gmc - motion completed callback control
10.5.2 Using Homing Commands
10.5.2.1 Homing Implementation
Figure 10-15: Homing Motion Algorithm