Owner's manual
Gold Cello Installation Guide
MAN-G-CELIG (Ver. 1.201)
||Auxiliary Power (J10)(optional)|www.elmomc.com
28
Table of Contents
To connect the auxiliary supply:
• The source of the auxiliary supply must be isolated.
• For safety reasons, connect the return (common) of the auxiliary supply source to the closest
ground near the auxiliary supply source.
• Connect the cable shield to the closest ground near the auxiliary supply source.
• Before applying power, first verify the polarity of the connection.
Figure 12: Separate Auxiliary Supply Connection Diagram