5.7. Communications
Specification Details
RS-232
Signals:
RxD , TxD , COMRET
Full duplex, serial communication for
setup and control
Baud Rate of 9,600 to 57,600 bit/sec
CAN
CAN bus Signals:
CAN_H, CAN_L, CAN_RET
Maximum Baud Rate of 1 Mbit/sec.
Version:
DS 301 v4.01
Layer Setting Service and Protocol Support:
DS 305
Device Profile (drive and motion control):
DS 402
EtherCAT
100base-T
Baud Rate: 100 Mbit/sec
CAT5 Cable
CoE, FoE, EoE
Ethernet
100base-T
Baud Rate: 100 Mbit/sec
CAT5 Cable
UDP, Telnet
USB
USB 2.0 Device mode
5.8. Pulse-Width Modulation (PWM)
Feature Details
PWM resolution Minimum 10-bit
Default 12-bit
Maximum 14-bit
PWM switching frequency on the load 2/Ts (factory default 40 kHz on the motor)