4.9.3. Port C Emulated Encoder Output (J2)
Port C provides emulated encoder output derived from port A or port B feedback inputs, or
from internal variables. The output options are:
Port A/B daisy chain (1:1) for incremental encoder
Encoder emulation: Emulate any input sensor, digital or analog, or use to emulate an
internal variable such as virtual profiler.
PWM output: any pair of outputs that is used as an encoder channel (e.g., channel A+ and
channel A-) can be configured by software to become PWM output.
Pulse & Direction output: The output pins that are assigned as channel A and channel B
when used as encoder out can be configured by software to become pulse and direction
outputs, respectively.
This port is used when:
The Gold Bell is used as a current amplifier to provide position data to the position
controller.
The Gold Bell is used in velocity mode to provide position data to the position controller.
The Gold Bell is used as a master in follower or ECAM mode.
Pin (J2) Signal Function
2 PortC_ENCO_A- Buffered Channel A- output/Pulse-
/PWM-
4 PortC_ENCO_A+ Buffered Channel A+ output /
Pulse+/PWM+
6 PortC_ENCO_B- Buffered Channel B- output / Dir-
8 PortC_ENCO_B+ Buffered Channel B+ output / Dir+
10 PortC_ENCO_INDEX- Buffered Channel INDEX- output
12 PortC_ENCO_INDEX+ Buffered Channel INDEX+ output
Table 16: Port C Pin Assignment