User Manual
Gold Bell Installation Guide Installation
MAN-G-BELIG (Ver. 1.004)
www.elmomc.com
41
4.7.4. Single Supply
A single isolated DC power supply can provide power for both the main power and the Auxiliary
(Drive Logic) Supply. The drawing below shows how a single supply is connected.
Figure 8: Single Supply for both the Main Power Supply and the Auxiliary Supply
4.7.5. Separate Auxiliary (Backup) Supply
Power to the Auxiliary Supply can be provided by a separate Auxiliary Supply.
Figure 9: Separate Auxiliary Supply Connection Diagram