Owner's manual

Gold Solo Hornet Installation Guide (EtherCAT and CAN) Product Description
MAN-G-SOLHORIG-EC (Ver. 1.009)
|www.elmomc.com
16
Table of Contents
2.2.10. Safety
IEC 61800-5-2, Safe Torque Off (STO)
Two STO (Safe Torque Off) inputs PLC level which can be configured to 5 V logic (available
on request)
Optically isolated
TTL Level (5 V logic)
Open collector and open emitter
UL 508C recognition
UL 60950 compliance
CE EMC compliance
2.2.11. Outputs
Two digital isolated output
2.2.12. Differential Outputs
Three differential outputs:
Port C EIA-422 differential output line transmitters
Response time < 1 μs
Output current: ± 15 mA.
2.2.13. Inputs
Six digital inputs conforms to PLC Standard
TTL Level (5 V logic)
Optically isolated
Fast digital capture data <5 μs
The six digital inputs can be configured to TTL mode (available on request, see
Section 5.5.1)
2.2.14. Differential Inputs
Six very fast differential event capture inputs 5 V logic
Via Port A or B (three on each port, depending on model)
EIA-422 Differential input line receiver
Response time < 1 μs
2.2.15. Analog Input
One Analog Inputup to 14-bit resolution
One Analog input: ±10 V