Chapter 3:
Technical Information
3.1. Physical Specifications
Feature Units All Types
Weight g (oz) 55 g (1.94 oz)
Dimension mm (in) 55 x 46 x 15 mm (2.2" x 1.8" x 0.6")
Mounting method PCB mount
3.2. Technical Data
Feature Units 1/100 2.5/100 5/100 10/100 15/100 20/100
Minimum supply voltage VDC 12
Nominal supply voltage VDC 85
Maximum supply voltage VDC 95
Maximum continuous power
output
W 80 200 400 800 1200 1600
Efficiency at rated power (at
nominal conditions)
% > 99
Maximum output voltage > 95% of DC bus voltage at f = 22 kHz
Auxiliary power supply VDC 12 to 95 VDC
(up to 6 VA inc. 5 V/2 x 200 mA for encoder)
Amplitude sinusoidal/DC
continuous current
A 1.0 2.5 5 10 15 20
Sinusoidal continuous RMS
current limit (Ic)
A 0.7 1.8 3.5 7 10.6 14.1
Peak current limit A 2 x Ic
Digital in/Digital out/Analog in 6/2/1
Table 1: Power Ratings
Note on current ratings: The current ratings of the Gold Hornet are given in units of DC
amperes (ratings that are used for trapezoidal commutation or DC motors). The RMS