Instruction Manual

Table Of Contents
Gold Hawk Installation Guide Technical Specifications
MAN-G-HAKIG (Ver. 1.001)
www.elmomc.com
82
5.5. Safe Torque Off (STO)
The Gold Hawk has two STO (Safe Torque Off) inputs.
5.5.1. STO Input Interfaces TTL Mode
Feature Details
Type of input Optically isolated
Input current for all inputs Iin = 3.8 mA @ Vin = 5 V
High-level input voltage 2.4 V < Vin < 15 V, 5 V typical
Low-level input voltage 0 V < Vin < 0.8 V
Minimum pulse width >3 ms
Figure 42: STO Input Schematic
5.6. Communications
Specification Details
RS-232
Signals:
RS232_Rx, RS232_Tx COMRET
Full duplex, serial communication for setup and control
Baud Rate of 9,600 to 57,600 bit/sec
Electrical Characteristic
Min
Type
Max
Unit
V
IH
High-level input voltage
2
3.3
V
V
IL
Low-level input voltage
0.8
V
V
OH
High-level output voltage
2.4
V
V
OL
Low-level output voltage
0.4
V
CAN
CAN bus Signals:
CAN_H, CAN_L, CAN_RET
Maximum Baud Rate of 1 Mbit/sec.
Version:
DS 301 v4.01