Table of Contents
CAN Network Communication Version (Part Number S or T)
Pin on P4 Signal Function
1 USB VBUS USB VBUS 5V
2 USBD+ USB _P line
3 USBD- USB _N line
4 COMRET Common Return
5 USB_SHIELD
6 RS232_TX- /RS422_TX- RS-232 Transmit/RS422 Transmit-(Differential RS-232)
7 RS422_RX+ RS422 Receive+(Differential RS-232)
8 Not in use Not in use
9 CANH CAN_H bus line (dominant high)
10 CANH CAN_H bus line (dominant high)
11 RS232_RX- /RS422_TX+ RS-232 Receive/ RS422 Transmit+(Differential RS-232)
12 RS422_RX- RS-422 RX-(Differential RS-232)
13 Not in use Not in use
14 CANL CAN_L bus line (dominant low)
15 CANL CAN_L bus line (dominant low)