5.3. Environmental Conditions
Feature Operation Conditions Range
Ambient
Temperature
Range
Non-operating conditions -50 °C to +100 °C (-58 °F to 212 °F)
Operating conditions -40 °C to +70 °C (-40 °F to 160 °F)
Temperature
Shock
Non-operating conditions -40 °C to +70 °C (-40 °F to 160 °F)
within 3 min.
Altitude Non-operating conditions Unlimited
Operating conditions -400 m to 12,000 m (-1312 to 39370 feet)
Maximum
Humidity
Non-operating conditions Up to 95% relative humidity non-condensing
at 35 °C (95 °F)
Operating conditions Up to 95% relative humidity non-condensing
at 25 °C (77 °F), up to 90% relative humidity
non-condensing at 42 °C (108 °F)
Vibration Operating conditions 20 Hz to 2,000 Hz, 14.6g
Mechanical
Shock
Non-operating conditions ±40g; Half sine, 11 msec
Operating conditions ±20g; Half sine, 11 msec