4.10. I/Os
The Panther has:
6 Digital Inputs
4 Digital Outputs
1 Analog Input
4.10.1. Digital Input Interfaces
The digital inputs are 5 V level compatible by default, but can be configured to PLC level, on the
integration board.
Feature Details
Type of input
Optically isolated
Each input has its own return
Input current for all inputs Iin = 4.7 mA @ Vin = 5 V
High-level input voltage 3.0 V < Vin < 10 V, 5 V typical
Low-level input voltage 0 V < Vin < 1 V
Minimum pulse width > 4 x TS, where TS is sampling time
Execution time (all inputs):
the time from application of
voltage on input until execution is
complete
If input is set to one of the built-in functions Home,
Inhibit, Hard Stop, Soft Stop, Hard and Soft Stop,
Forward Limit, Reverse Limit or Begin execution is
immediate upon detection: 0 < T < 4 x TS
If input is set to General input, execution depends on
program. Typical execution time: 0.5 msec.
High-speed inputs 5 & 6
minimum pulse width, in high-
speed mode
Capture Time (T) < 5 µsec
Notes:
Home mode is high-speed mode and can be used
for fast capture and precise homing.
High speed input has a digital filter set to the same
value as the digital filter (EF) of the main encoder.
The highest speed is achieved when turning on
optocouplers.
Figure 41: Digital Input Schematic