Owner's manual

Panther Installation Guide Technical Specifications
MAN-PANIG (Ver. 1.302)
www.elmomc.com
75
4.6. Auxiliary Supply
This table applies only to the models with an S option. See page 19 for further details on the
part number.
Feature Details
Auxiliary power supply Isolated DC source only
Auxiliary supply input voltage 18 to 30 VDC
Auxiliary supply input power 7 VA
Note: An S-option drive will not operate unless it has the Aux. supply (Mandatory).
4.7. Environmental Conditions
Feature Operation Conditions Range
Ambient
Temperature
Range
Non-operating conditions -50 °C to +100 °C (-58 °F to 212 °F)
Operating conditions -40 °C to +70 °C (-40 °F to 160 °F)
Temperature
Shock
Non-operating conditions -40 °C to +70 °C (-40 °F to 160 °F) within 3
min
Altitude
Non-operating conditions Unlimited
Operating conditions -400 m to 12,000 m (-1312 to 39370 feet)
Relative
Humidity
Non-operating conditions Up to 95% relative humidity non-
condensing at 35 °C (95 °F)
Operating conditions Up to 95% relative humidity non-
condensing at 25 °C (77 °F), up to 90%
relative humidity non-condensing at 42 °C
(108 °F)
Vibration
Operating conditions 20 Hz to 2000 Hz, 14.6 g
Mechanical
Shock
Non-operating conditions ±40 g; Half sine, 11 msec
Operating conditions ±20 g; Half sine, 11 msec