User Manual
Hawk Installation Guide Technical Specifications
MAN-HAWIG (Ver. 1.401)
www.elmomc.com
67
4.6. Environmental Conditions
Feature Operation Conditions Range
Ambient
Temperature
Range
Non-operating conditions -50 °C to +100 °C (-58 °F to 212 °F)
Operating conditions -40 °C to +70 °C (-40 °F to 160 °F)
Temperature
Shock
Non-operating conditions -40 °C to +70 °C (-40 °F to 160 °F) within 3
min
Altitude
Non-operating conditions Unlimited
Operating conditions -400 m to 12,000 m (-1312 to 39370 feet)
Maximum
Humidity
Non-operating conditions Up to 95% non-condensing humidity at 35 °C
(95 °F)
Operating conditions Up to 95% non-condensing humidity at 25 °C
(77 °F), up to 90% non-condensing humidity
at 42 °C (108 °F)
Vibration
Operating conditions 20 Hz to 2000 Hz, 14.6g
Mechanical
Shock
Non-operating conditions ±40g; Half sine, 11 msec
Operating conditions ±20g; Half sine, 11 msec