4.8. I/Os
The Falcon has:
• 10 Digital Inputs
• 5 Digital Outputs
• 2 Analog Input
4.8.1. Digital Input Interfaces
Feature Details
Type of input
• Optically isolated
• Single ended
• PLC level
Input current
* I
in
= 2.2 mA for V
in
= 12 V
Input current for high speed
inputs
* I
in
= 4.4 mA for V
in
= 12 V
High-level input voltage 12 V < V
in
< 30 V, 24 V typical
Low-level input voltage 0 V < V
in
< 6.5 V
Minimum pulse width > 4 x TS, where TS is sampling time
Execution time (all inputs):
the time from application of
voltage on input until
execution is complete
If input is set to one of the built-in functions — Home,
Inhibit, Hard Stop, Soft Stop, Hard and Soft Stop, Forward
Limit, Reverse Limit or Begin — execution is immediate
upon detection: 0 < T < 4 x TS
If input is set to General input, execution depends on
program. Typical execution time: ≅ 0.5 msec.
High-speed inputs - minimum
pulse width, in high-speed
mode
(IN5 - IN6)
T < 5 µsec
Notes:
• Home mode is high-speed mode and can be used for
fast capture and precise homing.
• High speed input has a digital filter set to same value as
digital filter (EF) of main encoder.
• Highest speed is achieved when turning on
optocouplers.