Manual
Falcon Installation Guide Installation
MAN-FALIG (Ver. 1.502)
www.elmomc.com
25
Figure 5: AC Motor Power Connection Diagram
3.4.2.2. Connecting the Main Power Cable
Connect the main power supply cable to the VP+ and PR terminals of the main power
connector. Connect the Protective Earth wire to the PE terminal on the Falcon’s heatsink.
Notes for connecting the DC power supply:
• Be sure to isolate the source of the DC power supply.
• For best immunity, it is highly recommended to use twisted cables for the DC power supply
cable. A 3-wire shielded cable should be used. The gauge is determined by the actual
current consumption of the motor.
• Connect both ends of the cable shield to the closest ground connection, one end near the
power supply and the other end to the PE terminal on the Falcon’s heatsink.
• For safety reasons connect the PR of the power supply to the closest ground connection.
Figure 6: Main Power Supply Connection Diagram