2.3.5. Feedback Options
• Incremental Encoder – up to 20 Megacounts (5 Mega-Pulse) per second
• Digital Halls – up to 2 kHz
• Incremental Encoder with Digital Halls for commutation – up to 20 Mega-Counts per
second for encoder
• Absolute Encoder
• Interpolated Analog (Sine/Cosine) Encoder – up to 250 kHz (analog signal)
Internal Interpolation – programmable up to x4096
Automatic Correction of:
• amplitude mismatch
• phase mismatch
• signals offset
Encoder outputs, buffered, differential.
• Resolver
Programmable 10 to 15 bit resolution
Up to 512 revolutions per second (RPS)
Encoder outputs, buffered, differential
• Tachometer and Potentiometer
Two inputs for Tachometer Feedback:
Up to ±50 VDC
Up to ±20 VDC
Potentiometer Feedback:
0 V to 5 V voltage range
Resistance: 100 Ω to 1000 Ω
• Elmo drives provide supply voltage for all the feedback options.
2.3.6. Fault Protection
The Falcon includes built-in protection against possible fault conditions, including:
• Software error handling
• Status reporting for a large number of possible fault conditions
• Protection against conditions such as excessive temperature, under/over voltage, loss of
commutation signal, short circuits between the motor power outputs and between each
output and power input/return
• Recovery from loss of commutation signals and from communication errors