User Manual
Eagle HV Installation Guide Technical Specifications
MAN-EAG-HVIG (Ver. 1.502)
www.elmomc.com
77
4.8.2. Velocity Loop
Feature Details
Controller type PI
Velocity control
• Fully digital
• Programmable PI and FFW control filters
• "On-the-fly" gain scheduling
• Automatic, manual and advanced manual tuning
Velocity and position feedback
options
• Incremental Encoder
• Absolute encoder (optional)
• Digital Halls
• Interpolated Analog (Sin/Cosine) Encoder (optional)
• Resolver (optional)
• Tachometer and Potentiometer (optional)
Note: With all feedback options, 1/T with automatic
mode switching is activated (gap, frequency and
derivative).
Velocity loop bandwidth < 350 Hz
Velocity sampling time
140 to 200 µsec (2x current loop sample time)
Velocity sampling rate Up to 8 kHz; default 5.5 kHz
Velocity command options
• Analog
• Internally calculated by either jogging or step
Note: All software-calculated profiles support on-the-fly
changes.
4.8.3. Position Loop
Feature Details
Controller type “1-2-4” PIP
Position command options
• Software
• Pulse and Direction
• Analog Potentiometer
Position loop bandwidth < 80 Hz
Position sampling time
280 to 400 µsec (4x current loop sample time)
Position sampling rate Up to 4 kHz; default 2.75 kHz