4.1.6. Input/Output
1 Analog Inputup to 14-bit resolution
6 programmable Digital Inputs, optically isolated (two of which are fast event capture
inputs).
Inhibit/Enable motion
Software and analog reference stop
Motion limit switches
Begin on input
Abort motion
Homing
General-purpose
4 programmable Digital Outputs:
Brake Control with output-current of 0.25 A
Amplifier fault indication
General-purpose
Servo enable indication
Buffered and differential outputs of the main encoder with up to 5 MHz pulses
Buffered and differential outputs of the auxiliary encoder
Emulated Buffered and differential outputs of resolver or analog encoder
Pulse and Direction inputs (Differential)
PWM current command output for torque and velocity
4.1.7. Built-In Protection
Software error handling
Abort (hard stops and soft stops)
Status reporting
Protection against:
Shorts between motor power outputs
Shorts between motor power outputs and power input/return
Failure of internal power supplies
Over-heating
Continuous temperature measurement. Temperature can be read on the fly; a
warning can be initiated x degrees before temperature disable is activated.
Over/Under voltage
Loss of feedback
Following error
Current limits