4.1.6. Input/Output
• 1 Analog Input – up to 14-bit resolution
• 6 programmable Digital Inputs, optically isolated (two of which are fast event capture
inputs).
Inhibit/Enable motion
Software and analog reference stop
Motion limit switches
Begin on input
Abort motion
Homing
General-purpose
• 4 programmable Digital Outputs:
Brake Control with output-current of 0.25 A
Amplifier fault indication
General-purpose
Servo enable indication
• Buffered and differential outputs of the main encoder with up to 5 MHz pulses
• Buffered and differential outputs of the auxiliary encoder
• Emulated Buffered and differential outputs of resolver or analog encoder
• Pulse and Direction inputs (Differential)
• PWM current command output for torque and velocity
4.1.7. Built-In Protection
• Software error handling
• Abort (hard stops and soft stops)
• Status reporting
• Protection against:
Shorts between motor power outputs
Shorts between motor power outputs and power input/return
Failure of internal power supplies
Over-heating
• Continuous temperature measurement. Temperature can be read on the fly; a
warning can be initiated x degrees before temperature disable is activated.
Over/Under voltage
Loss of feedback
Following error
Current limits