The Eagle HV must be installed in a suitable environment and properly connected to its voltage
supplies and the motor.
3.1. Before You Begin
3.1.1. Site Requirements
You can guarantee the safe operation of the Eagle HV by ensuring that it is installed in an
appropriate environment.
Feature Value
Ambient operating temperature -40 °C to +70 °C (-40 °F to 160 °F)
Maximum operating altitude 12,000 m (39370 feet)
Maximum non-condensing humidity 95%
Operating area atmosphere No flammable gases or vapors permitted in area
Caution:
The Eagle HV dissipates its heat by natural convection. The maximum ambient
operating temperature of 0 °C to 40 °C (32 °F to 104° F) must not be
exceeded.
3.1.2. Hardware Requirements
The components that you will need to install your Eagle HV are:
Component Connector Section
Drawing
Main Power Cable VP+ N VN- 3.5.3
Motor Cable M3 M2 M1 PE 3.5.3