jjj. Ensure that in normal operating conditions, the shielded wires and drain carry no
current. The only time these conductors carry current is under abnormal conditions,
when electrical equipment has become a potential shock or fire hazard while
conducting external EMI interferences directly to ground, in order to prevent them
from affecting the drive. Failing to meet this requirement can result in
drive/controller/host failure.
kkk. After completing the wiring, carefully inspect all wires to ensure tightness, good solder
joints and general safety.
The Cornet has the following connectors:
Type Function Port on Cornet Connector Location
8-Pin RJ-45 RS-232 COMM. 1
AC3AC2AC1PEM3M2M1
FEEDBACK B
FEEDBACK A
ANALOG INPUTS
COMMITTED I/O
COMM.2
GENERAL I/O
COMM.1
COR0018A
PE
9-Pin D-Sub socket Analog Input ANALOG INPUTS
8-Pin RJ-45, RJ-45 CAN … CAN
(CAN)
COMM. 2
15-Pin high-density D-
Sub plug
Digital Inputs COMMITTED I/O
15-Pin high-density D-
Sub socket
Digital Outputs GENERAL I/O
15-Pin D-Sub socket Main feedback FEEDBACK A
15-Pin D-Sub plug Auxiliary Feedback FEEDBACK B
2-Pin terminal strip
Molex
Auxiliary power
supply
+,
8-Pin terminal block
Molex
Mains and motor
power
M1, M2, M3, PE,
PE, AC1, AC2, AC3
Table 1: Connectors on the Cornet