1.10.2.2. Recommended Wire Cross-Sections (All Models)
Feature Connection Details
AC input
AC1, AC2, AC3
2.0 mm
2
14 AWG
Motor
M1, M2, M3
2.0 mm
2
14 AWG
Protective earth
PE, PE
2.0 mm
2
14 AWG
Auxiliary power +, – 0.5 to 1 mm
2
18 to 24 AWG
1.10.2.3. Power Connectors
Component Connector Described
in Section
Photo
Main Power Cable
PE, AC1, AC2, and AC3 on
Power Connector
1.13.2.2
Motor Cable
M1, M2, M3, PE
on Power Connector
1.13.2.1
Auxiliary Power
Cable
+, −
1.13.3
1.10.2.4. Communication Connectors
Component Port on Cornet Described
in Section
Drawing
RS-232
Communication
Cable
COMM. 1 1.13.9.1
CAN Communication
cable(s)
COMM. 2 1.13.9.2