- DBP SERIES USER MANUAL

35
DBP - Rev 6/93
Control board - cont.
H & R Function Remarks
9a Forward limit switch
This committed input activates the #[ subroutine.
*
9b positive input of a
differential amplifier.
See Appendix C.
10a Reverse limit switch
This committed input activates the #[ subroutine.*
10b Negative input of a
differential amplifier.
See Appendix C.
11a Circuit common
11b Output of a
differential amplifier.
See Appendix C.
12a Home switch
*
12b Tachogenerator
output/input
When using the resolver option this output is the
velocity monitor with a scale of 8V for maximum
speed. See 7.3.
13a Abort input
This input must be connected to high level voltage
to enable the amplifier.*
13b Output 1
**
14a Circuit common
14b Output 2
**
15a Fast input 6
This fast response input can capture events with a
duration of less than 10ยตs. An event is defined as
an input voltage transition from low to high. *
15b Output 3
**
16a Fast input 7
Same function as Fast Input 6 (15a). *
16b Output 4
**
17a Reset input
*
17b Output 5
**
*
Vil<1V, Vih>2.4V, Maximum input voltage: +30VDC
**
Vol<0.4V, Voh>4V, Output level: 0-5V, max output current +5mA