RSU-200 Remote Control Extension Unit for PTC-200C / PTC-100S / PTC-110R INSTRUCTION MANUAL PART NAMES Infrared Sensor LED DC IN RS-232C IN Terminal Composite Video Out (RCA pin jack) Camera IN
DIP SWITCH SETTING Be sure to turn ON No.1 of the DIP Switch(4) on the bottom of the Camera before turning ON the power supply to the Camera.
INTERNAL SWITCH When the unit is used for a long distance, select "LONG" ON the internal switch of RSU-200. It is recommended to use the unit within 500m(1640 ft) from PTC Cameras when the 5C-2V cable is used. SPECIFICATIONS Power source Power consumption Operating temperature Operating humidity Outside dimensions Weight 12V DC 2.5W 32 degF - 104 degF 30% - 85% 98mm(H)x96mm(D)x36mm(H) 3.8in.(H)x3.8in.(D)x1.4in.(H) 300g (0.
RS-232C SPECIFICATIONS Pin assignment Pin No. Code Name 1 DTR Data Terminal Ready 2 DSR Data Set Ready 3 TXD Transmitted Data 4 GND Ground 5 RXD Received Data 6 GND Ground 7 NC 8 NC - RS-232C Connector Transmission specifications * Full duplex start-stop sync. mode.