Hardware Setup tab will be displayed. In the example above, Control 2 will be activated after the motion has been
detected in area1.
7. If desired, associate selected detection area with another channel:
a.
In the Associated with Channel frame, click the Browse button in the Channel # field to select the
desired channel from the list. Only channels activated in the Hardware Setup tab will be displayed.
b.
Click the Browse button in the Preset # field to select the desired preset from the list. (Please see
Programming Presets section for more information).
Associated channel will assume this position when motion is detected by Intelli-Zone in the selected detection
area.
In the example above, Channel 3 will assume Preset 5 if the motion has been detected in the area1 on Channel
#1.
8.
Click the Save button to save the configured settings
Caution
Ensure there is NO MOTION occurring in the
defined area when clicking the Save button,
otherwise the Intelli-Zone™ function will not
work properly for that area. This is due to
that fact that Intelli-Zone™ detects changes
in the pixels that make up an image as op-
posed to detecting actual motion. When the
Save button is clicked, Intelli-Zone™ re-
gisters the current image as the default im-
age. All consequent changes to that area
will be registered. If motion occurs in the
defined area when the Save button is
clicked, even the static environment will set
off the alarm.
Related Topics: PTZ mode | Hardware Setup-Control Settings | Motion Setup
1.3.18. IP Camera
1.3.18.1. Overview
Assuming the user has an IP camera module present on LAN (Local Area Network) or WAN (Wide Area Network), addi-
tional cameras can be added to ELMO-PRO Server through a LAN or WAN.
Important
Even though the IP modules located on
WAN are supported, it is highly recommen-
ded to use IP modules on LAN ONLY. Since
the Internet connection is a lot less reliable
than the network connection, the video re-
cording is a lot more stable and reliable on
LAN.
The IP camera function is designed to work with the IP camera module. Currently ELMO-PRO Server supports the following
IP modules: Annexxus104, Annexxus204, and Annexxus101M.
Caution
Only one module type can be used at the
same time.
SONY and ELMO IP cameras are also supported.
Annexxus104 module supports the following resolutions:
1. 320X240 (max. 4 video inputs per IP module; max. 30 fps per input)
2. 640x240 (max. 3 video inputs per IP module; max. 30 fps per input)
3. 720x480 (max. 1 video input per IP module; max. 30 fps per input)
80ELMO-PRO v.1.403.16 - User Manual
IP CameraChapter 1. ELMO-PRO Server
XML to PDF by RenderX XEP XSL-FO Formatter, visit us at http://www.renderx.com/