Installation guide
Hornet and Bee Installation Guide  Technical Specifications 
MAN-HRBEIG (Ver. 1.3) 
www.elmomc.com 
63 
4.6.  Feedbacks 
The Hornet and Bee can receive and process feedback input from diverse types of devices. 
4.6.1.  Feedback Supply Voltage 
The Hornet and Bee have two feedback ports (Main and Auxiliary). The drives supply voltage 
only to the main feedback device. The user must provide a separate power supply for auxiliary 
feedback devices if needed. 
Feature  Details 
Main encoder supply voltage  5 V +5% @ 200 mA maximum 
4.6.2.  Main Feedback Options 
4.6.2.1.  Incremental Encoder Input 
Feature  Details 
Encoder format 
•  A, B and Index 
•  Differential 
•  Quadrature 
Interface   RS-422 
Input resistance 
Differential: 120 Ω 
Maximum incremental encoder frequency  Maximum absolute: 5 MHz pulses  
Minimum quadrature input period (PIN)  112 nsec  
Minimum quadrature input high/low period 
(P
HL) 
56 nsec  
Minimum quadrature phase period (PPH)  28 nsec 
Maximum encoder input voltage range 
Common mode: ±7 V 
Differential mode: ±7 V 