Installation guide
Hornet and Bee Installation Guide  Technical Specifications 
MAN-HRBEIG (Ver. 1.3) 
www.elmomc.com 
55 
4.1.5.  Feedback Options 
•  Incremental Encoder – up to 20 Mega-Counts (5 Mega-Pulse) per second 
•  Digital Halls – up to 2 kHz 
•  Incremental Encoder with Digital Halls for commutation – up to 20 Mega-Counts per 
second for encoder 
•  Interpolated Analog (Sine/Cosine) Encoder – up to 250 kHz (analog signal) 
  Internal Interpolation - up to x4096 
  Automatic Correction of amplitude mismatch, phase mismatch, signal offset 
  Emulated encoder outputs, single-ended, unbuffered of the Analog encoder 
•  Analog Hall Sensor 
•  Resolver 
  Programmable 10 to 15 bit resolution 
  Up to 512 revolutions per second (RPS)  
  Emulated encoder outputs, single-ended, unbuffered of the Resolver. 
•  Auxiliary Encoder inputs (ECAM, follower, etc.) single-ended, unbuffered. 
•  Tachometer & Potentiometer 
•  Provide power (5 V, 200 mA max) for one Encoder, Resolver or Hall. 
4.1.6.  Input/Output 
•  One Analog Input – up to 14-bit resolution 
•  Six programmable Digital Inputs, optically isolated (two of which are fast event capture 
inputs). 
  Inhibit/Enable motion 
  Software and analog reference stop 
  Motion limit switches 
  Begin on input 
  Abort motion 
  Homing 
  General-purpose 
•  Two programmable Digital Outputs, optically isolated (open collector) one with fast output 
compare (OC) 
  Brake Control 
  Amplifier fault indication 
  General-purpose 
  Servo enable indication 
•  Pulse and Direction inputs (single-ended) 
•  PWM current command output for torque and velocity 