3.8.3.  Shared Supply 
A "Main" DC Power Supply can be designed to supply power to the drive's Logic as well as to 
the Main Power (see Figure 8). If backup functionality is required (for storing control 
parameters in case of power-outs) an additional backup supply can be connected by 
implementing 'diode coupling' (see the Aux. Backup Supply in Figure 10). 
Figure 10: Shared Supply Connection Diagram 