5-5 DI/DO
Click on the DI/DO icon and select the total number of DI/DO installed on your system to see
the following figure:
[DI Status]
Choose Disable, NC, or NO according to your DI device (e.g., photo sensor).
Disable: Disable the DI function.
NC (normal closed): The signal loop is closed under normal conditions. When the loop
becomes open, DI will be triggered until the loop becomes closed again. In other words, if
the loop keeps on open for a period of time, DI will keep on triggering in that time
interval.
NO (normal open): The signal loop is open under normal conditions. When the loop
becomes closed, DI will be triggered until the loop becomes open again. In other words, if
the loop keeps on closed for a period of time, DI will keep on triggering in that time
interval.
[DO Status]
Disable: Disable the DO function.
Enable: Enable the output signal when DO is triggered.
Set the duration of DO signal. The available durations are 5, 10, 30, 60, 120, 300, 600,