user manual

A.3 Power Ratings
Feature
Units
70/48 70/60 R90/60 50/100 R75/100 35/200 R60/200 18/400
Minimum supply voltage VDC 11 14 23 46 92
Nominal supply voltage VDC 42 50 85 170 340
Maximum supply voltage VDC 48 59 95 195 390
Maximum continuous
power output
W 2700 3400 4300 4000 6000 5600 9600 5600
Efficiency at rated power
(at nominal conditions)
% > 97
Maximum output voltage 97% of DC bus voltage at f=22 kHz
Amplitude sinusoidal/DC
continuous current
A 70 70 90 50 75 35 60 18
Sinusoidal continuous
RMS current limit (Ic)
A 50 50 63 35 53 25 42 12.7
Peak current limit
A 2 x Ic 2 x Ic No Peak 2 x Ic No Peak 2 x Ic No Peak 2 x Ic
Weight g (oz) 700 g (24.7 oz)
Dimensions mm (in) 134 x 95 x 60 (5.3" x 3.7" x 2.4")
Digital in/Digital
out/Analog in
6/2/1
Mounting method Panel mount
A.4 Environmental Conditions
Feature Details
Ambient operating temperature 0 °C – 40 °C (32 °F – 104°F)
Storage temperature -20 °C – 85 °C (-4 °F – +185 °F)
Maximum humidity 90% non-condensing
Protection level
Drum Installation Guide Drum Technical Specifications
MAN-DRUIG (Ver. 1.0)