Installation guide

Whistle/Tweeter Installation Guide Installation
MAN-WHTWIG (Ver. 1.5)
3-33
3.13 Powering Up
After the Whistle or Tweeter is connected to its device, it is ready to be powered up.
Caution:
Before applying power, ensure that the DC supply is within the specified range
and that the proper plus-minus connections are in order.
3.14 Initializing the System
After the Whistle/Tweeter have been connected and mounted, the system must be set up
and initialized. This is accomplished using the Composer, Elmo’s Windows-based software
application. Install the application and then perform setup and initialization according to
the directions in the Composer Software Manual.
3.15 Heat Dissipation
The best way to dissipate heat from the Whistle is to mount it so that its heatsink faces up.
For best results leave approximately 10 mm of space between the Whistle's heatsink and
any other assembly.
3.15.1 Whistle Thermal Data
Heat dissipation capability (θ): Approximately 10 °C/W.
Thermal time constant: Approximately 240 seconds (thermal time constant means
that the Whistle will reach 2/3 of its final temperature after 4 minutes).
Shut-off temperature: 86 °C – 88 °C (measured on the heatsink)
3.15.2 Heat Dissipation Data
Heat Dissipation is shown in graphically below: