Installation guide
Whistle/Tweeter Installation Guide Installation
MAN-WHTWIG (Ver. 1.5)
3-6
3.5 Integrating the Whistle or Tweeter on a PCB
The Whistle and Tweeter are designed to be mounted on a PCB, either by soldering its pins
directly to the PCB or by using suitable socket connectors. In both cases the following rules
apply:
3.5.1 Traces
1. The size of the traces on the PCB (thickness and width) is determined by the
current carrying capacity required by the application.
The rated continuous current limit (Ic) of the Whistle and Tweeter is the current
used for sizing the motor traces (M1, M2, M3 and PE) and power traces (VP+, PR
and PE).
For control, feedbacks and Inputs/ outputs conductors the actual current is very
small but “generous” thickness and width of the conductors will contribute to a
better performance and lower interferences.
2. The traces should be as short as possible to minimize EMI and to minimize
the heat generated by the conductors.
3. The spacing between the high voltage conductors (VP+, PR, M1, M2, M3, VL)
must be at least:
Surface layer: 1.5 mm
Internal layer: 0.10 mm
Complying with the rules above will help satisfy UL safety standards, MIL-STD-275 and
the IPC-D-275 standard for non-coated conductors, operating at voltages lower than 100
VDC and at "unlimited altitudes" (above 10,000 meters – 30,000 feet).