Maintenance and repair
7.2 Maintenance work
Interval Maintenance to be carried out Section
monthly Check the pipes and screws for leaks and to ensure they are
seated properly and if necessary seal again or tighten up.
—
monthly Check the cooling water system and the pipes. —
monthly Check the terminal box and cable inlet holes for leaks and if
necessary re-seal.
—
monatlich Kühlrippen der Maschine und des Motor reinigen. —
monthly Check the oil level 7.2.1
7,500 h Changing the oil
depending on how dirty the
discharged medium is
Clean intake air fi lter
Clean gas ballast valve fi lter
7.2.2
at least once a year Check for coupling wear 7.2.3
monthly Check the cooling water system and the pipes. 7.2.4
depending on how dirty the
cooling liquid is
Clean dirt trap