Manual

Rietschle Thomas GmbH + Co. KG page 23 / 23
APPENDIX 6
REPORT ON MEASUREMENT OF THE COMPACT UNIT OSCILLATION POWER
The picture shows the measurement points for the blower
and electric motor. It is necessary to respect the point
marking for simplification of mutual communication.
Vd2 Ad1 Vd3 Am6
Vm6
Hd3
Hd4
Vd4
Hd2
Hd1
Vd1
Hm6
Hm5
Vm5
Vibration Measurement
Vibration values - total value / Frequency [Hz] - Vibration value
C.V. F V.F. F V.F. F V.F. F
Measurement
point
[mm / s] [Hz] [mm / s] [Hz] [mm / s] [Hz] [mm / s] [Hz]
Vd
Hd
1
Ad
Vd
Hd
2
-
Vd
Hd
3
-
Vd
Hd
4
-
Vm
Hm
5
-
Vm
Hm
6
Am
The aggregates must be measured twice a year.