Manual

Installation
610.44434.40.000 20 / 32 © Gardner Denver Deutschland GmbH
5.3.3 Procedure when connecting
pipes/hoses
Attach the pipes/hoses to the unit as described in the
following. The pipes/hoses are connected differently to
inlet and discharge connections depending on the
muffler design and the type of line (pipe or hose):
Muffler with inside threads:
The pipe is screwed directly into the muffler.
Muffler without inside thread:
Screw threaded flange (available as an
accessory) onto the muffler.
Screw the pipe into the threaded flange.
Hose connection:
for 2BH1 Screw the hose flange (available
as an accessory) onto the silencer.
Push the hose onto the hose flange and secure
it with a hose clamp. See Chapter 3.1,
"Mechanical data", Section "Tightening torques
for screw connections", Pg. 10 for information on
this topic.